-40%
Keatec Energy UPS 20kVA 3 Phase 380V
$ 2006.4
- Description
- Size Guide
Description
PRODUCT OVERVIEWSmall footprint online double
conversion Tower UPS with three
level charging.
T Series UPS is the ideal
power system for Industrial
applications, banking, and
Small Medium Enterprise
(SME) servers, computers and
communication systems
FEATURES
Clean power
Transformerless online double conversion UPS with sine wave output
Frequency converter mode
Low energy consumption
High input power factor of 0.99 minimizes energy consumption
ECO Mode available for increased energy savings
Advanced battery management
Three level intelligent charging up to 10A
Displays estimated battery runtime
Tests for battery capacity
Flexible and compatible
Small foot print compact tower, up to four units in parallel
Color LCD in multiple languages with mini diagrams and 1,000 event history
Wide input voltage compatible with low grid or generator voltage
UPS management PC software - Muser 4000
TRANSFORMERLESS ONLINE DOUBLE CONVERSION UPS
Power Options
Matching external battery tower
Parallel cable
Management Options
Dry contact relay
SNMP card
Keatec Energy Model T-3320E
Capacity 20kVA/18kW
Efficiency < 94.5%
Charge current 2.7 A (10 A)
(B model)
DC voltage +96/108/120 (+120)
(B model)
Internal battery. 20 x 12V 9AH x 2 (<4 minutes)
B model (estimate
back up time)
Bypass breaker 40A
Net weight Kg S (H) 171 (64)
H x W x L mm 868 x 250 x 828
One Year Warranty
FEATURES
Clean power
Transformerless online double conversion UPS with sine wave output Frequency converter mode
Low energy consumption
High input power factor of 0.99 minimizes energy consumption
ECO Mode available for increased energy savings
Advanced battery management
Three level intelligent charging up to 10A
Displays estimated battery runtime
Tests for battery capacity
Flexible and compatible
Small foot print compact tower, up to four units in parallel
Color LCD in multiple languages with mini diagrams and 1,000 event history Wide input voltage compatible with low grid or generator voltage
UPS management PC software - Muser 4000
Power Options
Matching external battery tower
Parallel cable
AC Input
Rated 380/400/415 Vac 50/60 Hz (3Ph+N+PE)
Voltage range 208 - 478 Vac
Input power factor >0.99
Input frequency 45 - 66 Hz (auto)
Current THD <3% at full load, non-linear
Bypass range 220 V max +25% (+10%, +15%, +20%), 230 V max +20% (+10%, +15%), 240 V max +15% (+10%)
V min -45% (-10%, -20%, -30%), Hz max +10%, Hz min -10%
AC Output
Rated voltage 380/400/415 Vac 50/60 Hz (3Ph+N+PE)
Power factor 0.9
Output frequency 50 Hz or 60 Hz synchronous with the network / 50 Hz or 60 Hz + 0.2 Hz selectable for battery mode or
frequency converter
THD <2% linear load, <5% non-linear load
Crest factor 3:1
General Specifications
Communication RS232, RS485, USB, dry contact, communications slot (2), parallel port (2), photocouple contact
Protocol / software Megatec, Modbus over RS232 / Muser4000
Noise <58dB
Temperature Operating 0 to +40° C, Storage -25 to +55° C
Altitude >1500 m output is de-rated
Humidity ≤95% non‑condensing
Standards
Safety / EMC IEC 62040-1 / IEC 62040-2, IEC 61000-2-2, IEC 61000-3-11, IEC 61000-3-12, 61000-4-2,
IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11